AAV2 Titration ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Qty
AAV-A002-96tests
$550.00
ETA of in-stock products:2 business days

Product Details

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    AAV2
    Format
    96T
    Regulatory Status
    RUO
    Sensitivity
    <3.13E+07 capsids/mL
    Standard Curve Range
    1.00E+09 capsids/mL-3.13E+07 capsids/mL
    Assay Time
    3 hr 20 min
    Suitable Sample Type
    For the detection and quantitative detection and quantitative determination of AAV2 capsid titration in AAV gene therapy product preparation processing.
    Sample volume
    100 μL

  • Product Overview

    AAV2 Titration ELISA Kit is based on the sandwich-ELISA method and is used to detect and quantitatively determine the AAV2 capsid titration in AAV gene therapy product. The kit is designed to provide reliable solutions for the early development, production, and quality control of AAV gene therapy products.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    The unopened kit is stable for 12 months from the date of manufacture if stored at 2°C to 8°C.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    AAV02-C01
    Pre-coated Anti-AAV2 Antibody Microplate
    1 plate
    AAV02-C02
    AAV2 Standard
    5.00E+10 capsids
    AAV02-C03
    Biotin-Anti-AAV2 Antibody
    15 μg
    AAV02-C04
    Streptavidin-HRP
    50 μL
    AAV02-C05
    10×Washing Buffer
    50 mL
    AAV02-C06
    2×Dilution Buffer
    50 mL
    AAV02-C07
    Substrate Solution
    12 mL
    AAV02-C08
    Stop Solution
    7 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     AAV2 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
  • Dilution Linearity

    To assess the linearity of the assay, samples spiked with high concentrations of AAV2 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

     AAV2 DILUTION LINEARITY
  • Intra-Assay Statistics

    Three samples of known concentration were tested ten times on one plate to assess intra-assay precision.

     AAV2 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples of known concentration were tested in three separate assays to assess inter-assay precision.

     AAV2 INTER-ASSAY STATISTICS
  • Recovery

    Three AAV2 with different concentrations were tested to calculate the recovery rate.

     AAV2 RECOVERY
  • Specificity

    The specific binding of AAV-A002 to AAV1/2/3/5/6/8/9/dj serotypes was detected. The results showed that AAV-A002 only binds specifically to AAV2.

     AAV2 SPECIFICITY

    The specific binding of AAV-A002 to native/denatured AAV2 was detected. The results showed that AAV-A002 only binds specifically to native AAV2. (Denatured AAV2: 95℃ for 5min)

     AAV2 SPECIFICITY

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews