Acrobiosystems for English
icon_bulk_orderBulk inquiry/Quick order
0
There is no goods in the shopping cart !
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: Home > Kits > Nuclease > CRS-A016

resDetect™ GENIUS™ Nuclease ELISA Kit (Residue Testing)

For research use only.

Order Now

Product Details
Assay TypeSandwich-ELISA
AnalyteNuclease
Format96T
Regulatory StatusRUO
Sensitivity< 39 pg/mL
Standard Curve Range39.06 pg/mL-2500 pg/mL
Assay Time3 hr 20 min
Suitable Sample TypeFor the quantitative determination the residue of nuclease in biologicals.
Sample volume100 μL
Materials Provided
IDComponentsSize
CRS016-C01Pre-coated Anti-Nuclease Antibody Microplate1 plate
CRS016-C02Nuclease Standard50 μL
CRS016-C03Biotin-Anti-Nuclease Antibody100 μL
CRS016-C04Streptavidin-HRP50 μL
CRS016-C0510xWashing Buffer 50 mL
CRS016-C062xDilution Buffer50 mL
CRS016-C07Substrate Solution12 mL
CRS016-C08Stop Solution7 mL
  • Background
    GENIUS™Nuclease ELISA Kit is based on ELISA sandwich method and designed for quantitative determination the residue of nuclease in biologicals. It contains Nuclease and a pair of antibodies against the eneyme, which are provided by ACROBiosystems. Results are obtained by four parameter logistic curve that were parallel to the standard curves obtained. The verification results indicate that this kit can be used for the quantitative determination of nuclease concentrations.
  • Application

    The GENIUS™ELISA Kit was developed for the detection and quantitative determination of nuclease in samples from downstream processing where nuclease is used as a process or purification aid.

    The  limitation of detectable dose (LOD) of Cat. No. CRS-A016 was determined as 2.733 pg/mL.

    It is for research use only.

  • Reconstitution
    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
  • Storage & Shipping
    Unopened kit should be stored at 2°C -8°C upon receiving.

    Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

    The kit shipped at room temperature that had been validated. Please contact us if you need blue ice shipping, but additional freight may be followed.

    Below is the Shipping Statement for Kit Products.

    Shipping Statement

  • Assay Principles
    This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Nuclease. The kit consists of Pre-coated Anti-Nuclease Antibody Microplate and Nuclease Standard and Biotin-Anti-Nuclease Antibody and Streptavidin-HRP and buffers.

    Your experiment will include 6 simple steps:

    a) All reagents were returned to room temperature(20°C-25°C) before use.

    b) Add your sample to the plate, take the Nuclease as standard sample. The samples and standard sample are diluted by Dilution Buffer.

    c) Add a diluted Biotin-Anti-Nuclease Antibody to the plate. The diluted by Dilution Buffer.

    d) Wash the plate and add a diluted Streptavidin-HRP to the plate. The diluted by Dilution Buffer.

    e) Wash the plate and add TMB.

    f) Stop the substrate reaction by add diluted acid. Absorbance (OD) is calculate as the absorbance at 450 nm minus the absorbance at 630 nm to remove background prior to statistical analysis. The OD Value reflects the amount of protein bound.

Typical Data Please refer to DS document for The assay protocol.
 Nuclease TYPICAL DATA

For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

 Nuclease TYPICAL DATA

GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A016) can detect the nuclease from different manufacturers with similar sensitivity.

 Nuclease TYPICAL DATA

GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A016) can detect the nuclease in different culture supernatant with similar curve and sensitivity.

 Nuclease TYPICAL DATA

GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A016) can detect the nuclease from different culture supernatant and was free from the matrix effects. * means a significant difference compared with the negative, NS means no significant difference with the negative.

Validation
Precision

Intra-Assay Precision : Twenty replicates of each of three samples containing different concentrations were tested in one assay. Within the detection range, the CV is less than 10%.
Inter-Assay Precision : Three replicates of each of three samples containing different concentrations were tested in three independent assays. Within the detection range, the CV is less than 10%.

 Nuclease PRECISION
Recovery

Three parts of blank medium were added with three different concentrations of Nuclease, and the medium without Nuclease was used as background to calculate the recovery rate.

 Nuclease RECOVERY
  • Background: Nuclease
    Nucleases are enzymes that degrade nucleic acids, either DNA or RNA. It has been used for the preparation of nuclear extracts by digesting DNA and releasing nuclear proteins intimately associated with DNA. It has also been designed for removing RNA and DNA in biotechnological processing. Thus, the amount of residual nuclease in biological products should be detected and limited.
  • Clinical and Translational Updates

Comments (0)


ETD of in-stock products: 2 business days

Price(USD) : $650.00

Promotion & Exhibitions



Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message