Human Integrin α4β7 / MAdCAM-1 Inhibitor Screening Kit (TR-FRET)

Customer Reviews
Cat. No. / Size
Price
Qty
FRT-P013-100tests
$770.00
FRT-P013-500tests
$2080.00
ETA of in-stock products:2 business days

Product Details

  • FAB

    1. Simple and fast operation - No complicated washing steps, significantly reducing time.
    2. High batch consistency - Strict control over raw materials and finished product quality, ensuring a stable supply.
    3. Accurate and reliable results - High sensitivity with minimal matrix effects.
    4. High throughput capability - Support multiple product specifications, ideal for high-throughput screening.
    5. Fast completion - Results in just 1.5 hours.
  • Product Specifications

    Assay Type
    Competition-TR-FRET
    Reactivity
    Human
    Regulatory Status
    RUO
    Assay Time
    1.5 hr
    Sample volume
    10 μL

  • Product Overview

    The Human Integrin α4β7 / MAdCAM-1 Inhibitor Screening Kit (TR-FRET) is based on a homogeneous (no wash) competition TR-FRET technology (Time-Resolved Fluorescence Resonance Energy Transfer) to screen for inhibitors of human Integrin α4β7 binding to MAdCAM-1 within 1.5 hours. It can also be used as a universal detection tool to identify the ability of human Integrin α4β7 to bind to human MAdCAM-1.

  • Storage

    1. Store the unopened kit at 2-8°C upon receipt.

    2. Locate the expiration date on the outer packaging and do not use reagents beyond their expiration date.

    3. The opened kit should be stored according to the storage conditions listed in the Components Table. The shelf life of the opened kit is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    FRTP013-C01
    Human MAdCAM-1 Protein Europium-chelate
    100 tests/500 tests
    FRTP013-C02
    FA Labeled Human Integrin α4β7 Protein
    100 tests/500 tests
    FRTP013-C03
    Anti-Human Integrin α4β7 Antibody
    30 μg/100 tests 150 μg/500 tests
    FRTP013-C04
    TR-FRET Sample Dilution Buffer, pH7.4
    50 mL/100 tests & 500 tests
    FRTP013-C05
    TR-FRET Detection Buffer, pH7.4
    50 mL/100 tests & 500 tests
    FRTP013-C06
    Signal Enhancer
    8 mL/100 tests & 500 tests

  • Assay Principles

    This Human Integrin α4β7 / MAdCAM-1 Inhibitor Screening Kit (TR-FRET) is based on TR-FRET technology (Time-Resolved Fluorescence Resonance Energy Transfer). This assay uses the mixture of biotinylated human MAdCAM-1 and Europium-chelate labeled streptavidin as the Donor and FA Labeled Human Integrin α4β7 Protein as the Acceptor.

    — When the sample does not contain the inhibitors that block the binding of human Integrin α4β7 to human MAdCAM-1, the Donor and Acceptor are in close proximity because of the binding of human Integrin α4β7 and human MAdCAM-1. Upon Donor excitation with light of a specific wavelength (337 nm), in addition to Donor emission (620 nm), non-radiative transfer of energy occurs between Donor and Acceptor, resulting in Acceptor emission (665 nm).

    — When the sample contains the inhibitors that block the binding of human Integrin α4β7 to human MAdCAM-1, the components inhibit the binding between the Donor and Acceptor and thereby prevent FRET from occurring.

    Assay Principles
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Bioactivity-TR-FRET 

    Please refer to DS document for the assay protocol.

     Integrin alpha 4 beta 7 TR-FRET

    In this TR-FRET assay, Human MAdCAM-1 Protein Europium-chelate is used as the Donor and FA Labeled Human Integrin α4β7 Protein is used as the Acceptor. An inhibition Assay was performed to evaluate the interaction between human I MAdCAM-1 and human Integrin α4β7 using Anti-Human Integrin α4β7 Antibody resulting in a typical IC50 of 3.963 nM (QC tested).

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Development Progress
  • English Name:

    Integrin alpha-4/beta-7

  • Category:

  • Approved Drugs:

    4 Details

  • Drugs in Clinical Trials:

    14 Details

  • Highest Development Stage:

    Approved

Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland