Product Details
Source
Anti-Mouse IgG-Acridinium ester is a chimeric monoclonal antibody recombinantly expressed in human 293 cells(HEK293), which combines the variable regions of a mouse monoclonal antibody with rabbit IgG constant domains.
Antibody Type
Recombinant Monoclonal
Clone
AS163
Isotype
Rabbit IgG, Kappa
Host Species
Mouse
Conjugate
Acridinium ester conjugated
Specificity
This product is a specific antibody specifically reacts with Mouse IgG.
Purification
Protein A purified.
Aggregation
Less than 10%, as determined by SEC-MALS.
Concentration
Please refer to the Certificate of Analysis (CoA).
Form
Lyophilized
Formulation
Lyophilized from a 0.22 μm-filtered solution in PBS, pH6.3, with trehalose as protectant.
Please contact us for customized product forms or formulations.
Reconstitution
Please refer to the Certificate of Analysis (CoA) for specific instructions.
Shipping
Lyophilized product is shipped at ambient temperature.
Storage
For long term storage, the product should be stored in a lyophilized state at -20°C or lower.
Please protect from light and avoid repeated freeze-thaw cycles.
This product is stable after storage at:
- -20°C to -70°C for 12 months in lyophilized state;
- -70°C for 3 months under sterile conditions after reconstitution.
Notices
Product Specific Notices: For research use only.
ACRO Quality Management System
Customers Also Viewed
Performance Data
Bioactivity-MPCLIA

Immobilized 0.04 μg /Test of Biotinylated Human PD-1, Avitag,His Tag (recommended for biopanning) (Cat. No. PD1-H82E4) to the Streptavidin-Magnetic Beads (used for MPCLIA) (Cat. No. MPC-A006, 20 μg beads/Test), incubated with 100 μL /Test of Human PD-L1, Mouse IgG1 Fc Tag, low endotoxin (Cat. No. PD1-H52A3) at increasing concentration coupled to Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163, 0.04 μg /Test). Detection was performed with sensitivity of 1.5625 ng/mL in Magnetism particulate chemiluminescence immunoassay (MPCLIA) (KEYSMILE, SMART 6500S) (QC tested).
Protocol
The MPCLIA assay shows that Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163) is stable at 37°C for 48 hours.
Protocol
The MPCLIA assay shows that Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163) is stable after freezing and thawing 3 times.
Protocol
Customer Reviews Writing Reviews

FAQ
- product
Can lyophilized proteins remain stable during room-temperature shipping or temporary room-temperature exposure?
In general, lyophilized proteins remain stable during room-temperature shipping or temporary exposure to room-temperature conditions.
Many ACROBiosystems recombinant proteins are supplied in lyophilized (freeze-dried) form. The lyophilization process effectively removes moisture from the product, helping reduce degradation-related reactions and improve protein stability during transportation and storage.
To evaluate the stability of lyophilized proteins under normal temperature conditions, ACROBiosystems conducted a stability study on 11 representative lyophilized protein products at 37°C. The study demonstrated that these proteins maintained good quality stability after storage at 37°C for approximately 20 days. Based on these validation results, temporary room-temperature exposure during shipping or handling is generally not expected to have a significant impact on product quality or downstream application performance.
To ensure optimal long-term stability, products should be stored according to the storage conditions specified in the product Certificate of Analysis (COA) upon receipt.
Supporting Document
Background
However, in traditional chemiluminescent immunoassay (CLIA),microplate was applied to immobilize antigen or antibody by physical absorption, which holds a negative effect on the perfor-mance of assay because of the low specific surface area of micro-plate.
The use of micromagnetic particles (MMPs) have proven to be a support for addressing the shortage of traditional CLIA mentioned above The chemiluminescent immunoassay is a technique used for disease diagnosis, drug development, chemical reaction monitoring, and many other applications.
The MMPs-based chemiluminescence immunoassays could improve the surface area for immobilization, capture efficiency and accuracy of the assay, thus obtaining higher sensitivity and shorter analysis time.