Product Details

    1. Genetically modified cell lines best reflect MOA (Mechanism of Action)
    2. Higher activity and larger assay window for robust and reproducible cell-based bioassay
    3. Comprehensive application data to support assay development and validation
    4. Full tracible record, stringent quality control and validated cell passage stability
    5. Parental cell line legally obtained from internationally recognized cell resource bank and commercially licensed
    6. Global commercial license assistance whenever regulatory filing is required
  • Description

    The Human BDCA2 (Luc) Jurkat Reporter Cell was engineered to not only express NFAT signaling response element, but also express the receptor full length human BDCA2 (Uniprot: Q8WTT0-1). When cocultured with anti-human BDCA2 agonist antibody, the interaction of agonist antibody and BDCA2 on the surface of Human BDCA2 (Luc) Jurkat Reporter Cell results in NFAT-mediated luminescence.

  • Application

    • Screen for anti-human BDCA2 agonist antibody

  • Growth Properties

    Suspension

  • Selection Marker

    Puromycin (5 μg/mL) + Hygromycin B (20 μg/mL)

  • Complete Growth Medium

    RPMI-1640 + 10% FBS

  • Freeze Medium

    Serum-free cell cryopreservation medium

  • Quantity

    1 vial contains at least 5×10^6 cells in 1 mL serum-free cryopreservation medium

  • Storage

    Frozen in liquid nitrogen.

  • Mycoplasma Testing

    Negative

  • Sterility Testing

    Negative

  • Instructions for Use

    See data sheet for detailed culturing and assay protocol.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Receptor Assay

     BDCA2 FACS

    Expression analysis of human BDCA2 on Human BDCA2 (Luc) Jurkat Reporter Cell by FACS.
    Cell surface staining was performed on Human BDCA2 (Luc) Jurkat Reporter Cell or negative control cell using PE-labeled anti-human BDCA2 antibody.

    Protocol
  • Application

     BDCA2 APPLICATION

    Agonistic activity analysis of anti-human BDCA2 antibody (RLU).
    This reporter cell was incubated with serial dilutions of antibodies in the presence of CHO cells or CHO/Human CD32b Stable Cell Line (Medium Expression) (Cat. No. SCCHO-ATP060M). The EC50 of Litifilimab determined in the presence of CHO cells was approximately 0.4915 μg/mL, and in the presence of CHO/Human CD32b Stable Cell Line (Medium Expression) was approximately 0.1866 μg/mL. These results demonstrate that Litifilimab can activate BDCA2 signaling independent of CD32b-mediated crosslinking, but the presence of CD32b can enhance BDCA2 signaling.

    Protocol
  •  BDCA2 APPLICATION

    Agonistic activity analysis of anti-human BDCA2 antibody (FOLD).
    This reporter cell was incubated with serial dilutions of antibodies in the presence of CHO cells or CHO/Human CD32b Stable Cell Line (Medium Expression) (Cat. No. SCCHO-ATP060M). The max induction fold of Litifilimab determined in the presence of CHO cells was approximately 81.03, and in the presence of CHO/Human CD32b Stable Cell Line (Medium Expression) was approximately 190.72. These results demonstrate that Litifilimab can activate BDCA2 signaling independent of CD32b-mediated crosslinking, but the presence of CD32b can enhance BDCA2 signaling.

    Protocol
*Please contact us if you are interested in related cell pool service.

Customer Reviews
Writing Reviews

Important Statement

  • Limited Use&License Disclosure

    BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE FOLLOWING TERMS OF LIMITED USE OF THIS CELL LINE PRODUCT.

    1. If the researcher is not willing to accept the terms of limited use of this cell line product, and the product is unused, ACRO will accept return of the unused product.
    2. Researchers may use this product for research use only, no commercial use is allowed. "Commercial use" means any and all uses of this product and derivatives by a party for profit or other consideration and may include but is not limited to use in: (1) product manufacture; and (2) to provide a service, information or data; and/or resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research.
    3. This cell line is neither intended for any animal or human therapeutic purposes nor for any direct human in vivo use. You have no right to share, modify, transfer, distribute, sell, sublicense, or otherwise make the cell line available for use to other researchers, laboratories, research institutions, hospitals, universities, or service organizations.
    4. ACROBIOSYSTEMS MAKES NO WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THE SUITABILITY OF THE CELL LINE FOR ANY PARTICULAR USE.
    5. ACROBIOSYSTEMS ACCEPTS NO LIABILITY IN CONNECTION WITH THE HANDLING OR USE OF THE CELL LINE.
    6. Modifications of the cell line, transfer to a third party, or commercial use of the cell line may require a separate license and additional fees. Please contact order@acrobiosystems.com for further details.

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
  • Important Statement
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland