resDetect™ BSA ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Qty
RES-A001-
Inquiry
ETA of in-stock products:2 business days

Product Details

  • FAB

    1. Rapid - Results can be obtained within 90 minutes.
    2. Reference Standard Traceability - The reference standard is traceable to the National Standard NIFDC (cat # 140619).
    3. Rigorous Method Validation - Validation reports compliant with ICH guidelines can be provided upon request.
    4. High Sensitivity - Sensitivity for Bovine Serum Albumin (BSA) is < 0.5 ng/mL.
    5. Strong Specificity - No cross-reactivity with non-target proteins.
    6. Excellent Buffer Compatibility - Compatible with a wide range of buffer systems.
  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    BSA (Bovine serum albumin)
    Format
    96T (8×12 strips)
    Regulatory Status
    RUO
    Sensitivity
    <0.5 ng/mL
    Standard Curve Range
    0.5 ng/mL-40.5 ng/mL
    Assay Time
    1.5 hr
    Suitable Sample Type
    For the quantitative determination of BSA (Bovine serum albumin)
    Sample volume
    50 μL
    Assay Type
    Sandwich-ELISA
    Analyte
    BSA (Bovine serum albumin)
    Format
    96T (8×12 strips)
    Regulatory Status
    RUO
    Sensitivity
    <0.5 ng/mL
    Standard Curve Range
    0.5 ng/mL-40.5 ng/mL
    Assay Time
    1.5 hr
    Suitable Sample Type
    For the quantitative determination of BSA (Bovine serum albumin)
    Sample volume
    50 μL

  • Product Overview

    resDetect™ BSA ELISA Kit is based on the ELISA sandwich method and is used to detect and quantitatively determine Bovine Serum Albumin (BSA) residues in biological products. This kit is designed to support optimal purification process development and routine quality control of in-process streams and final products in various biotechnological processes, such as cell and tissue culture. The standard BSA has been calibrated against the NIFDC standard (cat # 140619) to ensure accurate assay results. It can also be used as a universal detection tool for the quantitative determination of BSA.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    RES01-C01
    Pre-Coated Anti-BSA Antibody Microplate
    1 plate (8×12 strips)
    RES01-C02A
    BSA (Bovine serum albumin) Standard (200ng/mL)
    500 μL
    RES01-C02B
    BSA (Bovine serum albumin) Standard 5 (40.5ng/mL)
    500 μL
    RES01-C02C
    BSA (Bovine serum albumin) Standard 4 (13.5ng/mL)
    500 μL
    RES01-C02D
    BSA (Bovine serum albumin) Standard 3 (4.5ng/mL)
    500 μL
    RES01-C02E
    BSA (Bovine serum albumin) Standard 2 (1.5ng/mL)
    500 μL
    RES01-C02F
    BSA (Bovine serum albumin) Standard 1 (0.5ng/mL)
    500 μL
    RES01-C02G
    BSA (Bovine serum albumin) Standard 0 (0ng/mL)
    500 μL
    RES01-C03
    HRP-Anti-BSA Antibody
    100 μL
    RES01-C04
    1×Sample Dilution Buffer
    50 mLX2
    RES01-C05
    20×Washing Buffer
    25 mL
    RES01-C06
    Substrate Solution
    12 mL
    RES01-C07
    Stop Solution
    8 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     BSA TYPICAL DATA

    Detection of BSA ( Bovine serum albumin) by ELISA Assay.
    Immobilized Anti-BSA Antibody can bind BSA (Bovine serum albumin) Detection was performed using HRP-Anti- BSA Antibody with sensitivity of 0.5 ng/mL (QC tested). For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
  • Intra-Assay Statistics

    Three samples of known concentration were tested ten times on one plate to assess intra-assay precision , Intra-Assay Precision CV≤15%.

     BSA INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples of known concentration were tested in ten separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.

     BSA INTER-ASSAY STATISTICS
  • Accuracy

    Five samples of known concentration were tested ten times to assess Accuracy , Accuracy recovery rate 80-120%.

     BSA ACCURACY
  • Interference effect

    We have conducted interference effect test about frequently-used buffers, they have excellent buffer compatibility. For specific buffers, it is recommended that you verify recovery to determine the minimum dilution ratio.

     BSA INTERFERENCE EFFECT
  • Specificity

    High, medium and low concentrations of BSA were added to Human serum (v/v 1%), Horse serum (v/v 10%) , Human Serum Albumin (1.25 mg/mL) and Rabbit serum (v/v 10%), the recovery rate of BSA was used as the specific validation index.

     BSA SPECIFICITY

    High, medium and low concentrations of BSA were added to MDCK( 2×106 cells/mL), HEK293( 3.5×106 cells/mL) , CHO( 2×106 cells/mL) and T-lymphocyte( 2.15×106 cells/mL) the recovery rate of BSA was used as the specific validation index.

     BSA SPECIFICITY

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews