Human Th1/Th2 Cytokine Kit (Flow Cytometry Multiplex Bead Assay)

Customer Reviews
Cat. No. / Size
Price
Qty
FCM-C05R-96tests
$1545.00
ETA of in-stock products:2 business days

Product Details

  • Product Specifications

    Assay Type
    FACS
    Analyte
    IFN-γ, TNF-α, IL-10, IL-6, IL-4, IL-2
    Format
    96T
    Reactivity
    Human
    Regulatory Status
    RUO
    Sensitivity
    1.77 pg/ml (IFN-γ), 0.76 pg/ml (TNF-α), 0.27 pg/ml (IL-10), 0.78 pg/ml (IL-6), 0.65 pg/ml (IL-4), 0.70 pg/ml (IL-2)
    Standard Curve Range
    9.8-10000 pg/mL
    Assay Time
    3 hr
    Suitable Sample Type
    Human serum, Human plasma, Cell culture supernatants
    Sample volume
    10 μL

  • Product Overview

    T helper cells (Th) play a vital role in the adaptive immune system by suppressing or regulating immune responses. After Th actived, it will differentiate into T-helper 1 (Th1) or T-helper 2 (Th2) effector cells. These two subsets are characterized by their distinct cytokine expression pattern and the immune function they mediate. Th1 and Th2 cells each produce a specialized combination of cytokines that depends on type of pathogen that the helper T cell has recognized-some cytokines are more effective than others in the process of eliminating certain invaders. In general, TH1 cytokines play the role of immune killing, while Th2 cytokines play the role of immune protection. Th1/Th2 paradigm provides rationale for developing new vaccines against infectious diseases and novel strategies for the therapy of allergic and autoimmune disorders.

  • Application

    The Human Th1/Th2 Cytokine Kit can be used to quantitatively measure Interleukin-2 (IL-2), Interleukin-4 (IL-4), Interleukin-6 (IL-6), Interleukin-10 (IL-10), Tumor Necrosis Factor-α (TNF-α), and Interferon-γ (IFN-γ) protein levels in a single sample.The kit performance has been optimized for analysis of specific cytokines in tissue culture supernatants, EDTA plasma, and serum samples.

    It is for research use only.

  • Storage

    The unopened kit is stable for 18 months from the date of manufacture if stored at 2°C to 8°C.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    FCM05-C01
    Calibrator
    5 μg(for each)×2
    FCM05-C02A
    Human IL-2 Capture Beads
    96 tests
    FCM05-C02B
    Human IL-4 Capture Beads
    96 tests
    FCM05-C02C
    Human IL-6 Capture Beads
    96 tests
    FCM05-C02D
    Human IL-10 Capture Beads
    96 tests
    FCM05-C02E
    Human TNF-α Capture Beads
    96 tests
    FCM05-C02F
    Human IFN-γ Capture Beads
    96 tests
    FCM05-C03
    2×Assay Buffer
    40 mL
    FCM05-C04
    10×Wash Buffer
    10 mL
    FCM05-C05
    Detection antibody
    0.5 mL
    FCM05-C06
    96-well V-bottom plate
    1 plate
    FCM05-C07
    96-well Sealing film
    2 pieces
    FCM05-C08
    APC Positive Control
    0.5 mL
    FCM05-C09
    PE Positive Control
    0.5 mL

  • Assay Principles

    Human Th1/Th2 Cytokine 6-plex panel is a multiplex bead-based indirect immunofluorescence assay, utilizing flow cytometry for data acquisition and classification. The beads conjugated with specific antibody, target protein (IL-2/4/6/10, TNF-α, IFN-γ) in specimens and PE-conjugated detection antibody form a sandwiches complex as bead-analyte-detection antibody. The intensity of PE fluorescence signal in proportion to the target protein in specimens, are assessed by flow cytometry.The present assay has been optimized for quntitatively analysis for the IL-2/4/6/10, TNF-α, IFN-γ in cell culture supernatant, plasma, and serum samples.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     Th1/Th2 cytokine TYPICAL DATA

    A double logarithmic fitting curve was plotted for each cytokine( IL-2, IL-4, IL-6, IL-10, TNF-α, IFN-γ). The present curve of each cytokines was ranging from 9.8 pg/ml to 10000 pg/ml respectively .

  • Bioactivity-FACS 

    Please refer to DS document for the assay protocol.

     Th1/Th2 cytokine FACS

    A representative scatter plot showing single bead population in P1 gate (left), the beads conjugated with analyte-sepcific antibody differntiated by APC fluorescence intensity (middle), and fluorescence signal in propotion to concentration of the analyte was measured for each cytokine in PE channel (right). Data was generated on Beckman Cytoflex S Flow Cytometer, equipped with blue laser (488 nm) and red laser (640 nm).

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews