R-PE Antibody Labeling Kit

Customer Reviews
Cat. No. / Size
Price
Qty
ALK-A001-100ug
$295.00
ALK-A001-500ug
$595.00
ALK-A001-1mg
$750.00
ETA of in-stock products:2 business days

Product Details

  • Materials Provided

    ID
    Components
    Size
    ALK01-C01
    Modifier reagent
    1 vial
    ALK01-C02
    Activated PE
    1 vial
    ALK01-C03
    Quencher reagent
    1 vial

  • Product Overview

    R-Phycoerythrin (PE) is an orange fluorescent protein which has an excitation wavelength of 488 nm/561 nm and an emission wavelength of 575nm. R-PE Antibody Labeling Kit provides a rapid and simple method to covalently link via the interchain disulfide bonds of the antibody.

  • Application

    R-PE Antibody Labeling Kit uses a simple and quick process for PE conjugation of antibody. The conjugated antibody can be used straight away without further purification step and antibody loss.

    It is for research use only.

  • Storage

    1. Unopened kit should be stored at -20℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

  • Assay Principles

    PE Antibody Labeling Kit provides a rapid and simple method for achieving covalently coupling of PE and antibody molecules. The interchain disulfide bonds of the antibody can be modified to generate active cysteine residues, which are then conjugated with the preactivated PE to obtain the PE-antibody conjugate.

    Assay Principles
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Bioactivity-FACS 

    Please refer to DS document for the assay protocol.

     - FACS

    2.5e5 RC222 cells (anti-CD19 CAR-293 cells, G4S linker is used in CARs) and jurkat cells (with expression of the CD3 antigen) were stained with 100μL of 1μg/mL PE labeled antibody, and analyzed with FACS.
    The results show ALK-A001 can be used for different antibodies conjugation.

  • Bioactivity-FACS 

    Please refer to DS document for the assay protocol.

     - FACS

    Binding signal of products prepared by different size of PE antibody labeling Kit (ALK-A001). The result shows very high consistency (QC tested).

  •  - FACS

    The binding signal of PE labeled anti-FMC63 antibody using ALK-A001 Kit was higher than the other competitor kit (Routinely tested).

  •  - FACS

    The binding signal of PE labeled anti-CD3 antibody using ALK-A001 Kit was higher than the other competitor kit (Routinely tested).

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland