Acrobiosystems for English
icon_bulk_orderBulk inquiry/Quick order
0
There is no goods in the shopping cart !
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: Home > Kits > DLL4 > RES-A052

resDetect™ Human Fc Tag DLL4 ELISA KIT (Residue Testing)

For research use only.

Order Now

Product Details
Assay TypeSandwich-ELISA
AnalyteDLL4
Format96T
ReactivityHuman
Regulatory StatusRUO
Sensitivity< 18.75 pg/mL
Standard Curve Range18.75 pg/mL-1200 pg/mL
Assay Time3 hr 20 min
Suitable Sample TypeFor the quantitative determination of human DLL4 in Cell Culture Supernatants, Plasma, Serum.
Sample volume100 uL
Materials Provided
IDComponentsSize
RES052-C01Pre-coated Anti-DLL4 Antibody Microplate1 plate
RES052-C02Human Fc Tag DLL4 Standard20 μg
RES052-C03Biotin-Anti-DLL4 Antibody150 μL
RES052-C04Streptavidin-HRP50 μL
RES052-C0510xWashing Buffer 50 mL
RES052-C062xDilution Buffer50 mL
RES052-C07Substrate Solution12 mL
RES052-C08Stop Solution7 mL
  • Background
    Human Fc Tag DLL4 ELISA KIT is based on ELISA sandwich method and designed to measure human Fc Tag DLL4 levels in cell culture supernates, serum, and plasma. It contains recombinant human Fc Tag DLL4 and a pair of antibodies against the recombinant factor, which are provided by ACROBiosystems. Results are obtained by four parameter logistic curve that were parallel to the standard curves obtained. The verification results indicate that this kit can be used for the quantitative determination of GMP human Fc Tag DLL4 (ACROBiosystems, cat#GMP-DL4H28) concentrations. The specificity has been verified.
  • Application

    Human Fc Tag DLL4 ELISA KIT was developed for the detection and quantitative determination of GMP human Fc Tag DLL4(ACROBiosystems, cat#GMP-GMP-DL4H28) concentration.

    It is for research use only.

  • Reconstitution
    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
  • Storage
    Unopened kit should be stored at 2°C -8°C upon receiving.

    Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Assay Principles
    This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Human Fc Tag DLL4. The kit consists of Pre-coated Anti-DLL4 Antibody Microplate and Human Fc Tag DLL4 Standard and Biotin-Anti-DLL4 Antibody and Streptavidin-HRP and buffers.

    Your experiment will include 6 simple steps:

    a) Bring all reagents to room temperature(20℃-25℃) before use.

    b) Add your sample to the plate and take the Human Fc Tag DLL4 Standard. The samples and standard are diluted by Dilution Buffer.

    c) Wash the plate and add the Biotin-Anti-DLL4 Antibody diluted by Dilution Buffer to the plate.

    d) Wash the plate and add the Streptavidin-HRP diluted by Dilution Buffer to the plate.

    e) Wash the plate and add TMB.

    f) Stop the substrate reaction by adding diluted acid. Absorbance (OD) is calculated by the absorbance at 450 nm minus the absorbance at 630 nm to remove background disturbance before statistical analysis. The OD Value reflects the amount of bound protein.

Typical Data Please refer to Ds document for the assay protocol.
 DLL4 TYPICAL DATA

For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
Dilution Linearity

To assess the linearity of the assay, samples spiked with high concentrations of human Fc Tag DLL4 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

 DLL4 DILUTION LINEARITY
Intra-Assay Statistics

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision, Intra-Assay Precision CV<10%.

 DLL4 INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Three samples of known concentration were tested in three separate assays to assess inter-assay precision, Inter-Assay Precision CV<10%.

 DLL4 INTER-ASSAY STATISTICS
Recovery

Three parts of blank serum were added with different concentrations of human Fc Tag DLL4, and the serum without human Fc Tag DLL4 was used as background to calculate the recovery rate. The range of the recovery rate is 83.7-116.5%, and the average recovery is 98.6%.

 DLL4 RECOVERY
  • Background: DLL4
    Delta-like protein 4 (DLL4) is also known as Drosophila Delta homolog 4 (Delta4), which contains one DSL domain and eight EGF-like domains. DLL4 is expressed in vascular endothelium. DLL4 is involved in the Notch signaling pathway as Notch ligand, which can activates NOTCH1 and NOTCH4. DLL4 is involved in angiogenesis and negatively regulates endothelial cell proliferation and migration and angiogenic sprouting. DLL4 can bind to Notch-1 and Notch-4.
  • Clinical and Translational Updates

Comments (0)


ETA of in-stock products: 2 business days

Price(USD) : $348.00

Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:0 Details
  • Number of Drugs in Clinical Trials:3 Details
  • Latest Research Phase:Phase 3 Clinical

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop
Call us
Call us
North America:
+1 800-810-0816 (Toll Free)
Asia & Pacific:
+86 400-682-2521
Fax
Fax
+1 888-377-6111
Address
Address
1 Innovation Way, Newark, DE 19711, USA

Leave a message